mirror of
https://gitee.com/dlmu-cone/bf_original_balance_chassis
synced 2026-07-24 03:27:45 +08:00
修复LK电机反馈异常和总线拥塞的问题
This commit is contained in:
@@ -16,7 +16,7 @@ static void LKMotorDecode(CANInstance *_instance)
|
||||
static LKMotor_Measure_t *measure;
|
||||
static uint8_t *rx_buff;
|
||||
rx_buff = _instance->rx_buff;
|
||||
measure = &((LKMotorInstance *)_instance)->measure; // 通过caninstance保存的id获取对应的motorinstance
|
||||
measure = &(((LKMotorInstance *)_instance->id)->measure); // 通过caninstance保存的id获取对应的motorinstance
|
||||
|
||||
measure->last_ecd = measure->ecd;
|
||||
measure->ecd = (uint16_t)((rx_buff[7] << 8) | rx_buff[6]);
|
||||
@@ -59,7 +59,10 @@ LKMotorInstance *LKMotorInit(Motor_Init_Config_s *config)
|
||||
motor->motor_can_ins = CANRegister(&config->can_init_config);
|
||||
|
||||
if (idx == 0) // 用第一个电机的can instance发送数据
|
||||
{
|
||||
sender_instance = motor->motor_can_ins;
|
||||
sender_instance->tx_id = 0x280; // 修改tx_id为0x280,用于多电机发送,不用管其他LKMotorInstance的tx_id,它们仅作初始化用
|
||||
}
|
||||
|
||||
LKMotorEnable(motor);
|
||||
lkmotor_instance[idx++] = motor;
|
||||
|
||||
@@ -2,4 +2,6 @@
|
||||
|
||||
这是瓴控电机的模块封装说明文档。关于LK电机的控制报文和反馈报文值,详见LK电机的说明文档,由于电机实例已经自带三环PID计算,一般来说**我们能用到的只有单电机的力矩指令和多电机指令。**
|
||||
|
||||
注意LK电机在使用多电机发送的时候,只支持一条总线上至多4个电机,多电机模式下LK仅支持发送id 0x280为接收ID为0x140+id.
|
||||
注意LK电机在使用多电机发送的时候,只支持一条总线上至多4个电机,多电机模式下LK仅支持发送id 0x280为接收ID为0x140+id.
|
||||
|
||||
要设置为多电机模式,请通过串口连接电机,并使用该文件夹下的LK motor tool.exe进行配置。
|
||||
Reference in New Issue
Block a user